Daikin air conditioner repair and installation in Tashkent
S3 Air installs, repairs, cleans and refills Daikin air conditioners (a Japanese brand) in Tashkent and the Tashkent Region.
Warranty on all types of work. Technician visit and estimate in Tashkent are free.
Services for Daikin air conditioners
Typical problems customers call about
What to tell the technician when you contact us
- Brand and model of the air conditioner (shown on the label of the indoor unit)
- How old the air conditioner is and when it was last serviced
- What is happening: the symptom, the error code on the display, when it appears
- District and address, convenient visit time
How customers search for the service
"Daikin air conditioner repair"; "Daikin air conditioner not cooling"; "Daikin air conditioner installation in Tashkent"; "Daikin air conditioner cleaning".
Daikin air conditioner error codes
The table is based on the manufacturer's documentation. Codes depend on the series and model, so follow the manual for your unit.
| Code | Meaning | Applies to |
|---|---|---|
| U0 | Refrigerant shortage | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| U2 | Overvoltage detected | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| U3 | Signal transmission fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| U4 | No communication between the indoor and outdoor units | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| A1 | Indoor unit board fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| A5 | Freeze-up protection or high-pressure control | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| A6 | Indoor fan motor fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| C4 | Indoor coil temperature sensor fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| C9 | Room temperature sensor fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| E1 | Outdoor unit board fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| E3 | High-pressure protection tripped | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| E4 | 4-way valve fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| E5 | Compressor overload protection tripped | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| E6 | Compressor locked or failed to start | Daikin FTXM60β71A2V1B (wall-mounted splits) |
| H9 | Outdoor air temperature sensor fault | Daikin FTXM60β71A2V1B (wall-mounted splits) |
What to do: write down the code or the number of blinks, photograph the display if needed and call a technician. Do not open the units or touch the refrigerant lines. If you smell burning, switch the unit off at the mains.
Source: official Daikin installer reference guide for FTXM60β71A2V1B (daikin.eu).
Frequently asked questions
Do you repair Daikin air conditioners?
Yes, we accept requests for the repair of Daikin air conditioners. The technician diagnoses the unit on site; spare part availability depends on the model and is clarified after diagnostics.
How much does Daikin air conditioner repair cost?
Repair starts from 200,000 UZS. The technician names the final price after diagnostics, before the work starts.
How much does Daikin air conditioner installation cost?
Basic installation of a split system starts from 500,000 UZS. The technician names the final price after inspection.
How do I call a technician?
Call +998 97 882 70 75 or write in Telegram @S3air_bot. Tell us the model and describe the problem.
Other brands
Need a technician?
Call or write to us: tell us the air conditioner model, we will advise and book a convenient time.